ADX921AQFN32
- 
                                        Two low-noise PGAs and two 24-bit high-resolution ADCs analog ECG front-end 
Product details
- 
                                            Parameters 
- 
                                            Characteristics 
- 
                                            Package 
- 
                                            Description 
- 
                                            - 
                                                        Two PGAs and two 24-bit high-resolution ADCs 
- 
                                                        SPI communication with a sampling rate of 16 Ksps 
- 
                                                        -40°C to +85°C 
 
- 
                                                        
- 
                                            - 
                                                        • Three low-noise (ADX923) PGAs and two high-resolution ADCs (ADX922/3) 8.6μVPP (G = 6) 
 
- 
                                                        
- 
                                            - 
                                                        QFN32 4mm x 4mm 
 
- 
                                                        
- 
                                            The ADX920/1/2/3 devices are multichannel, simultaneously sampling, 24-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with built-in programmable gain amplifiers (PGA), internal reference, and oscillator. The ADX920/1/2/3 devices integrate all the features typically required for portable, low-power medical electrocardiogram (ECG), activity, and fitness applications. With high integration and superior performance, the ADX920/1/2/3 devices enable the creation of scalable medical instrument systems with significantly reduced size, power, and overall cost. Each channel of the ADX920/1/2/3 devices features a flexible input multiplexer that can be independently connected to internally generated signals for testing, temperature, and lead-off detection. Additionally, any input channel configuration can be designated to derive the right leg drive (RLD) output signal. The ADX920/1/2/3 devices operate at data rates up to 8 kSPS. Lead-off detection can be implemented within the device using the internal excitation current sink or source. The ADX922/3 devices include fully integrated respiration impedance measurement functionality. The specified operating temperature range is from –40°C to 85°C. 
Related applications
Related products
- 
                                        
                                            ADX920QAQFN32Automotive-grade, low-noise PGA and 24-bit high-precision ADC analog ECG front end 
- 
                                        
                                            ADX921QAQFN32Automotive-grade, two low-noise PGAs and two 24-bit high-precision ADC analog ECG front end 
- 
                                        
                                            ADX922QAQFN32Automotive-grade integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for an analog ECG front-end. 