ADX922AQFN32
- 
                                        Integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for analog ECG front-end 
Product details
- 
                                            Parameters 
- 
                                            Characteristics 
- 
                                            Package 
- 
                                            Description 
- 
                                            - 
                                                        Integrated respiration impedance, three PGAs, two 24-bit high-precision ADCs, SPI communication, sampling rate of 16 kSPS. 
- 
                                                        -40°C to +85°C 
 
- 
                                                        
- 
                                            - 
                                                        • Three low-noise (ADX923Q) PGAs and two high-resolution ADCs (ADX922Q/3Q) 
- 
                                                        • Input-referred noise 8.8μV (150Hz BW, G = 6) 
- 
                                                        • Data rate 125SPS至16kSPS 
 
- 
                                                        
- 
                                            - 
                                                        QFN32 4mm x 4mm 
 
- 
                                                        
- 
                                            The ADX920/1/2/3 devices are multi-channel, simultaneous sampling, 24-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with integrated programmable gain amplifiers (PGAs), internal references, and on-board oscillators. These devices incorporate all the features typically required in portable, low-power medical electrocardiogram (ECG), exercise, and fitness applications. With their high level of integration and exceptional performance, the ADX920/1/2/3 devices enable the creation of scalable medical instrumentation systems with significantly reduced size, power consumption, and overall cost. Each channel of the ADX920/1/2/3 devices has a flexible input multiplexer that can independently connect to internally generated signals for testing, temperature, and lead-off detection. Furthermore, any input channel configuration can be utilized to derive the right leg drive (RLD) output signal. The ADX920/1/2/3 devices operate at data rates up to 8 kSPS. Lead-off detection can be achieved using the device's internal excitation current sink or source. The ADX922/3 devices include fully integrated respiration impedance measurement functionality. The operating temperature range is specified from –40°C to 85°C. 
Related products
- 
                                        
                                            ADX920QAQFN32Automotive-grade, low-noise PGA and 24-bit high-precision ADC analog ECG front end 
- 
                                        
                                            ADX921QAQFN32Automotive-grade, two low-noise PGAs and two 24-bit high-precision ADC analog ECG front end 
- 
                                        
                                            ADX922QAQFN32Automotive-grade integrated respiration impedance, two low-noise PGAs, and two 24-bit high-precision ADCs for an analog ECG front-end. 